IndustryProject / LocationCountryCustomerYear
GDRM/PRMSMalsfeld-Ostheim (GER)GermanyE.on Mitte2014

The gas pressure control and measurement system is used to relieve the gas to a lower pressure level. Our filters and separators protect the sensitive measuring and control components from the finest dirt and liquid particles.

Technical Data:
ProductDust-Liquid Separator
TypeVSFA-V-PC 5.600.100.200.1
Quantity1 pcs
CodeAD 2000 + CE
P design100 bar
T design-10 / + 50 °C
Flow rate VN75.000 Nm³/h
Efficiency:99,9 % > 1µm
Weight2 tons
Technical Data:
ProductCartridge Filter
TypeVPF 2.400.100.200.1
Quantity1 pcs
CodeAD 2000 + CE
P design100 bar
T design-10 / + 50 °C
Flow rate VN75.000 Nm³/h
Efficiency:99,9 % > 2µm
Weight750 kg
IndustryProject / LocationCountryCustomerYear
CompressorIzhevskaya – Perm – Vladimirskaya (RU)RussiaBorsig ZM2012

These compressor stations are used to upgrade the existing steam power plants into combined cycle power plants (CCPP).
Thielmann successfully delivers a total of 12 skids for 3 stations to Russia and accompanies the commissioning on site together with the plant builder. Each design comprises complete separator skids including the discharge and monitoring instrumentation to the separator.

Technical Data:Izhevskaya
ProductDust-Liquid Separator
TypeVSFA-V-MC 36.1500.16.500.1
Quantity2 pcs
CodeAD 2000 + CE // GOST TR
P design16 bar
T design-45 / + 50 °C
Flow rate VN64.100 Nm³/h
Efficiency99,9 % > 1µm
Weight8 tons
Technical Data:Perm
ProductDust Liquid Separator
TypeVSFA-V-AC 22.1200.16.450.1
Quantity2 pc(s)
CodeAD 2000 + CE // GOST TR
P design16 bar
T design-45 / + 45 °C
Flow rate VN54.347 Nm³/h
Efficiency99,9 % > 1µm
Weight5,3 tons
Technical Data:Vladimirskaya
ProductDust Liquid Separator
Type 1VSFA-V-AC 11.800.16.300.1
Type 2VSFA-V-AC 18.1000.16.400.1
Quantityeach 2 pcs
CodeAD 2000 + CE // GOST TR
P design16 bar
T design-45 / + 45 °C
Flow rate VN35.255 Nm³/h
Efficiency99,9 % > 1µm
Weight2,2 + 3,2 tons
IndustryProject / LocationCountryCustomerYear
StorageCavern Storage Staßfurt (GER)GermanyRWE Service2011

April 2011

The Staßfurt cavern storage facility in Saxony-Anhalt supplies the ONTRAS transmission network and the distribution network of Mitgas GmbH.

RWE Gas Storage is expanding the cavern storage facility in 2 construction stages. Thielmann Energietechnik is supplying 1 heat exchanger for the withdrawal line.

Technical Data:
ProductHeat Exchanger
TypeVEV 900.11.200.500.2
Quantity1 pc(s)
CodeAD2000 + CE
P design200 bar
T design-25 to 120°C
Flow rate VN475.000 Nm³/h
Heat Capacity9,4 MW
Weight15,6 tons
SpecialsTotal Height: 7,7m
Straight Tube, vertical
Helium Test @ 6bar / tube welds
IndustryProject / LocationCountryCustomerYear
PipelineNorth-Stream-Pipeline Vyborg (RU) – Greifswald (GER)RussiaGazprom UHDE2011

Nord-Stream refers to the 1224 km long natural gas pipeline through the Baltic Sea from Vyborg in Russia to Lubmin near Greifswald in Germany. Uhde’s “GAS-In-Unit”, equipped with two Thielmann waterbath heaters, was successfully commissioned in September 2011 and September 2012 (pipeline strand 1+2).

The Russian head of government Mr. Putin as well as the chairman of the supervisory board of Nord Stream AG and former German chancellor Gerhard Schröder inspected the commissioning of the Gas-In-Unit and the water bath heaters.

Thielmann Energietechnik GmbH delivered two 4 MW Waterbath-Heaters, designed for 220 bar (approx. 35 t per heater without skid) in only five months. During the initial filling of the pipeline the gas temperature decreases due to the resulting pressure reduction (Joule-Thomson effect) when opening the “gas tap”. The heaters counteract this effect by warming up the gas and support the pressure build-up during the “gas-in” process in the “new” pipeline.

Technical Data:
ProductWaterbath-Heater
TypeVH 29.3300.850.150.200.1
Quantity2 pcs
CodeAD2000 + CE
P design220 bar
T design-31 to 100°C
Flow rate VN108.340 Nm³/h
Heat Capacity4 MW
Weight35 tons
SpecialsDelivery in only 5 month.
IndustryProject / LocationLand / Country
BiogasCell gas filter in biogas plants, fuel gas supplyworldwide

Biogas is processed in so-called biogas feed-in plants in order to be able to feed it into the public gas network. Here, our cell gas filters are integrated into the gas pressure control and metering lines to protect sensitive components, such as gas meters and control devices, from contamination.

If the biogas still contains traces of hydrogen, elevated hydrogen sulfide or ammonia as residual contamination from the raw biogas, we offer solutions for filtration, specially developed for biogas. All special solutions can also be executed in stainless steel.

Technical Data:
ProductCellular Gas Filters
TypeVZF DN 25 - DN 150
CodeDVGW certified
P design16 bar
T design-10 / + 70 °C
Flow rate VNtill 1.000 m³/h
Efficiency99,9 % > 1µm
Zellengasfilter in Biogasanlagen, Brenngasversorgung
IndustryProject / LocationCountryCustomerYear
PowerRiyadh (SA)Saudi ArabiaBilfinger Rotring2010

The heavy oil-fired power plant in Riyadh, Saudi Arabia, is designed for 2600 MW. In 2010, this power plant will be expanded with gas turbines, creating an additional 700 MW of capacity. By 2015, the power plant will be expanded to a total capacity of 4,600 MW, making it one of the largest combined cycle power plants in the world.

Technical Data:
ProductDust-Liquid Separator (Inletfilter)
TypeVSFA-V-PC 26.1250.70.450.1
Quantity3 pc(s)
CodeASME + U-Stamp
P design70 bar
T design-10 bis 85°C
Flow rate VN210.100 Nm³/h
Efficiency99,9 % > 1 μm
Weight9 tons
Specialsincl. ACID-Cleaning, c2=5mm
Technical Data:
ProductCyclone Separator (Scrubber)
TypeVZA 1000.70.450.a
Quantity3 pc(s)
CodeASME + U-Stamp
P design70 bar
T design-10 bis 85°C
Flow rate VN210.100 Nm³/h
Efficiency99,5 % > 10 μm
Weight4,8 tons
Specialsincl. ACID-Cleaning, c2=5mm
Technical Data:
ProductCondensate Tank
TypeVKAB 1600.3,5.8500
Quantity1 pc(s)
Volume8.500 liter