Industry | Project / Location | Country | Customer | Year |
GDRM/PRMS | Malsfeld-Ostheim (GER) | Germany | E.on Mitte | 2014 |
The gas pressure control and measurement system is used to relieve the gas to a lower pressure level. Our filters and separators protect the sensitive measuring and control components from the finest dirt and liquid particles.
Technical Data: | |
---|---|
Product | Dust-Liquid Separator |
Type | VSFA-V-PC 5.600.100.200.1 |
Quantity | 1 pcs |
Code | AD 2000 + CE |
P design | 100 bar |
T design | -10 / + 50 °C |
Flow rate VN | 75.000 Nm³/h |
Efficiency: | 99,9 % > 1µm |
Weight | 2 tons |
Technical Data: | |
---|---|
Product | Cartridge Filter |
Type | VPF 2.400.100.200.1 |
Quantity | 1 pcs |
Code | AD 2000 + CE |
P design | 100 bar |
T design | -10 / + 50 °C |
Flow rate VN | 75.000 Nm³/h |
Efficiency: | 99,9 % > 2µm |
Weight | 750 kg |